Flow meter avery hardoll BM 950 jual flowmeter
Call for Price
In StockJual Flow meter avery hardoll BM 950
Flowmeter Merk: Avery hardoll
Size: 3 inch
Description
Flow meter avery hardoll BM 950 jual flowmeter
FEATURES & BENEFITS
Avery-Hardoll BM Series BM950 flowmeters are precision made, positive displacement, liquid measuring instruments that maintain
the higest level of accuracy over a lifetime of operation. Simplicity of design and accuracy has resulted in the Avery-Hardoll BM Series
meters to being the most preferred meters by aviation fueling operators and airlines in internatonal markets.
Flow meter avery hardoll BM 950 jual flowmeter
TYPES OF BULKMETER | |
Series Number | |
Manifold Flow Rate | |
General Description | |
Inches Millimeters | |
Imperial | |
Gallons | |
Liters | |
BM250 2 – 2½ 63 25 – 250 115 – 1140 | |
Single Capsule Meters | |
BM950 3 76 30 – 300 130 – 1370 | |
BM450 3 76 45 – 450 200 – 2050 | |
BM550 4 102 50 – 500 220 – 2280 Double Capsule Meters | |
BM350 4 102 55 – 550 250 – 2500 | |
BM650 4 102 65 – 650 300 – 3000 | |
Triple Capsule Meters | |
BM750 6 152 65 – 650 300 – 3000 | |
BM850 6 152 85 – 1000 387- 4000 | |
Special Application Only for Low | |
Viscosity / Clean Aviation Fuel |
While conventional meters are calibrated at only one
flow rate, MASTERLOAD II™ and MASTERLOAD III™
calibration is corrected at a range of flow rates to provide
the highest level of accuracy. With a multitude of
calibration points across the full flow range, the system
allows the user the flexibility to configure
each system to suit the requirements of their
specific application.
VISCOUS PRODUCTS
Avery-Hardoll bulkmeters can be used on all petroleum
products of all viscosities. However, there is an increase in
pressure drop with more viscous fuels, which under normal
circumstances will limit the maximum flow rate obtainable.
It is recommended that the pressure drop through a
bulkmeter should not exceed 15 psi (1 bar), above which
the load on the bearings will start to cause wear.
Consequently when using products with viscosities
above 100 centistokes (at operating conditions), it
is necessary to reduce the maximum permitted
flow rate. As a guide, it is suggested that the
pressure drop through the meter should not
exceed 10 psi (0.7 bar) for continuous running
at maximum speed or 15 psi (1 bar) for
continuous running at half speed.