Sort By:
View:
  • Emergency Eyewash Haws 7500 | Jual Eyewash Portable haws 7500 cv.BungaToba

    Emergency eyewash Hwas 7500

    Download Katalog: haws 7500

    SPECIFICATIONS
    Model 7500 portable gravity operated eyewash shall include
    a FDA approved high-density green polyethylene 16 gallon
    (60.6 L) tank, ABS plastic eyewash heads with .4 gpm (1.5 L)
    flow rate over 15 minutes, yellow pull-down activation arm,
    integral handles on top and sides, wide-fill threaded cap,
    label-mounted operation and maintenance instructions, and
    a stainless steel wall bracket. Additive not included – Order
    separately.

    Call for Price
  • Eutech Con 150 Conductivity -Total Disoved solids -Temperatur

    Specification

    Conductivity
    Range 0 to 200 mS
    Resolution 0.01 μS to 0.1 mS
    Accuracy ±1 % full scale
    Calibration Auto/manual; 1 point/range
    TDS
    Range 0 to 200 ppt (TDS factor 1.0)
    Resolution 0.01 ppm to 0.1 ppt
    Accuracy ±1 % full scale
    Calibration Manual; 1 point/range
    Temperature
    Range -10.0 to 110.0 ºC (14.0 to 230.0 ºF)
    Resolution 0.1 ºC/ºF
    Accuracy ±0.5 ºC; ±0.9 ºF
    Calibration Offset in 0.1 increments, ±10 ºC or ±18 ºF
    Display Three line custom LCD
    Temperature
    Compensation Automatic or manual from -10 to 110 ºC
    Temperature
    Coefficient 0.0 to 10.0 %/ºC
    Memory Stores up to 150 data sets
    Power Two AA batteries (included), >500 hours continuous use;
    AC adapter (optional)
    Dimensions
    (L x W x H)
    Meter 77/8” x 31/8” x 2 ¼” (20 x 8.3 x 5.7 cm)
    Boxed 91/8” x 91/8” x 2 ¾” (23 x 23 x 7 cm)
    Weight Meter 1 lb (0.5 kg)
    Boxed 1.4 lb (0.7 kg)

    Call for Price
  • EUTECH CyberScan PCD 650 – jual eutech instrument-cv.Bunga Toba

    Call for Price
  • Eutech CyberScan PCD 650- Jual eutech instrument| cv bunga toba

    Specification:

    pH
    Range -2.000 to 20.000 pH –
    Resolution 0.1, 0.01, 0.001 pH –
    Accuracy ±0.002 pH –
    Calibration Points 1 (offset) to 6 points –
    Buffer Sets USA, NIST, DIN, PWB, Custom –
    Auto-Buffer Recognition Yes –
    Slope & Offset Display Yes –
    Ion
    Range 0.001 to 19900 –
    Resolution 2 to 3 digits –
    Accuracy 0.5 % full scale (monovalent); 1 % full scale (divalent) –
    Calibration Points Up to 8 –
    ORP
    Range ±2000.0 mV –
    Resolution 0.1 mV –
    Accuracy ±0.2 mV –
    Temperature
    Range -10.0 to 110.0 ºC/14.0 to 230.0 ºF (meter)
    Resolution 0.1 ºC/0.1 ºF
    Accuracy ±0.5 ºC/±0.9 ºF
    Conductivity
    Range
    .. to 2.000 μS/cm,
    2.000 μS/cm to 300.0 μS/cm,
    300.0 μS/cm to 4.000 mS/cm,
    4.000 mS/cm to 40.00 mS/cm,
    40.00 mS/cm to 500.0 mS/cm

    .. to 2.000 μS/cm,
    2.000 μS/cm to 300.0 μS/cm,
    300.0 μS/cm to 4.000 mS/cm,
    4.000 mS/cm to 40.00 mS/cm,
    40.00 mS/cm to 500.0 mS/cm
    Resolution 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm –
    0.01 μS/cm, 0.1 μS/cm,
    0.001 mS/cm, 0.01 mS/cm,
    0.1 mS/cm
    Accuracy ±1 % full scale of each range – ±1 % full scale of each range
    Calibration Points 4 (1 per range) auto,
    5 (1 per range) manual – 4 (1 per range) auto,
    5 (1 per range) manual
    Cell Constant (K) 0.010 to 10.000 – 0.010 to 10.000
    Temperature Coefficient Linear & pure – Linear & pure
    Normalisation Temperature 15 to 30 ºC – 15 to 30 ºC
    Auto-Ranging Yes – Yes
    TDS
    Range
    .. to 2.000 ppm,
    2.000 ppm to 300.0 ppm,
    300.0 ppm to 4.000 ppt,
    4.000 ppt to 40.00 ppt,
    40.00 ppt to 500.0 ppt

    .. to 2.000 ppm,
    2.000 ppm to 300.0 ppm,
    300.0 ppm to 4.000 ppt,
    4.000 ppt to 40.00 ppt,
    40.00 ppt to 500.0 ppt
    Resolution 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt – 0.01 ppm, 0.1 ppm, 0.001 ppt,
    0.01 ppt, 0.1 ppt
    Accuracy ±1 % full scale of each range – ±1 % full scale of each range
    Conversion Factor 0.4000 to 1.000 – 0.4000 to 1.000
    Salinity
    Range
    .. to 0.770 ppm,
    0.770 ppm to 143.3 ppm,
    143.3 ppm to 2.138 ppt,
    2.138 ppt to 23.64 ppt,
    23.64 ppt to 80.00 ppt

    .. to 0.770 ppm,
    0.770 ppm to 143.3 ppm,
    143.3 ppm to 2.138 ppt,
    2.138 ppt to 23.64 ppt,
    23.64 ppt to 80.00 ppt
    Resolution 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt – 0.01 ppm, 0.1 ppm,
    0.001 ppt, 0.01 ppt
    Accuracy ±1 % full scale of each range – ±1 % full scale of each range
    Resistivity
    Range
    2.000 Ω to 25.00 Ω,
    25.00 Ω to 250.0 Ω,
    250.0 Ω to 3.333 kΩ,
    3.333 kΩ to 500.0 kΩ,
    500.0 kΩ to 20.00 MΩ

    2.000 Ω to 25.00 Ω,
    25.00 Ω to 250.0 Ω,
    250.0 Ω to 3.333 kΩ,
    3.333 kΩ to 500.0 kΩ,
    500.0 kΩ to 20.00 MΩ
    Resolution 0.01 Ω, 0.1 Ω, 0.001 Ω, 0.1 Ω, 0.01 MΩ – 0.01 Ω, 0.1 Ω, 0.001 Ω, 0.1 Ω, 0.01 MΩ
    Accuracy ±1 % full scale of each range – ±1 % full scale of each range
    Dissolved Oxygen
    Range 0.00 to 90.00 mg/L or ppm – 0.00 to 90.00 mg/L or ppm
    Resolution 0.01 mg/L; 0.01 ppm – 0.01 mg/L; 0.01 ppm
    Accuracy ±0.2 mg/L – ±0.2 mg/L
    Calibration Points 1 – 1
    Probe Galvanic with integral
    temperature sensor – Galvanic with integral
    temperature sensor
    % Saturation of
    Oxygen
    Range 0 to 600.0 % – 0 to 600.0 %
    Resolution 0.1 % – 0.1 %
    Accuracy ±2.0 % – ±2.0 %
    Calibration Points 2-Point (0 %, 100 %) – 2-Point (0 %, 100 %)

    Call for Price
  • Eutech DO 6+| Jual DO Meter merk eutech|cv.Bunga Toba

    Product Specification

    Dissolved Oxygen Range 0 to 20.00 mg/l or ppm
    Resolution & Accuracy 0.01 mg/l or 0.01 ppm & ±1.5% Full Scale
    % Saturation of Oxygen 0.0 to 200/0 %
    Resolution & Accuracy 0.1% & ±1.5% Full Scale
    Temperature Range 0.0 to 50.0 °C (32 to 122 °F)
    Resolution & Accuracy 0.1 °C (0.1 °F) & ± 0.3 °C (0.5 °F)
    Salinity Correction 0.0 to 50.0 ppt
    Barometric Pressure Correction 500 to 1499 mmHg or 66.6 to 199.9 kPA
    Method Automatic correction after manual input
    No. of Calibration Points Up to 2 points; 100% in air and/or
    0% in known solution
    Special Functions Self-diagnostic; Electrode characteristics;
    Hold & Auto-Power Off after20 minutes
    Power Requirements 4 x 1.4V batteries; > 700 hrs

    Call for Price
  • Eutech pH 6+; Eutech pH 5+ – cv.Bunga Toba

    Specifications

    Product Specification

    Description
    pH Range 0.00 to 14.00 pH
    Resolution & Accuracy 0.01 pH & ± 0.01 pH
    Temperature Range 0 to 100.0 °C
    Resolution & Accuracy 0.1 °C & ± 0.5 °C
    mV Range -1000 to + 1000 mV
    Resolution & Accuracy 1 mV & ± 1 mV
    Temperature Compensation Automatic / Manual (0 to 100 °C)
    No. of Calibration Points Up to 5 points
    pH Buffer Options 1.68, 4.01, 7.00, 10.01, 12.45 (USA)
    1.68, 4.01, 6.86, 9.18, 12.45 (NIST)
    4.10, 6.97 (Pb)
    Special Functions Auto Power-Off after 17 minutes;
    Hold & Self-diagnostic messages
    Power 4 ‘AAA’ x 1.4V batteries
    Call for Price
  • pH meter atau alat pengukur keasaman suatu jat cair

    Merk: Eutech

    Tipe: ph 450

    DOWNLOAD KATALOG: pH450

    Specification Table

    pH : Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ±0.01 pH Calibration Up to 5 points (USA & NIST & CUSTOM) Up to 6 points (DIN)mV: Range ±2000 mV Resolution 0.1 mV ±999.9 mV; 1 mV beyond Accuracy ±0.2 mV +2 LSD or +0.5 % of reading; whichever is greater Calibration ±200 mV
    Ion: Range 0.0 to 2000 ppm Resolution 0.01 / 0.1 / 1 ppm Accuracy ±0.5 % full scale (monovalent); ±1 % full scale (divalent) Calibration From 2-4 or 2-5 points: 0.10, 1.00, 10.0, 100.0 & 1000 / 0.20, 2.00, 20.0, 200.0 & 2000 / 0.50, 5.00, 50.0 & 500.0
    Temperature: Range -10.0 to 110.0 ºC (14.0 to 230.0 ºF) Resolution 0.1 ºC Accuracy ±0.5 ºC; ±0.9 ºF Calibration Offset in 0.1 increments, ±10 ºC or ±18 ºF Display Custom LCD with backlight Memory Stores up to 500 data sets Output USB or RS232 Real-Time Clock Time and date stamp on calibration and stored data Temperature Compensation Automatic or manual from -10 to 110 ºC Power Two AA batteries (included), >500 hours (without backlight); AC adapter (optional) Dimensions (L x W x H) Meter 77/8” x 31/8” x 2 ¼” (20 x 8.3 x 5.7 cm) Boxed 91/8” x 91/8” x 2 ¾” (23 x 23 x 7 cm) Weight Meter 1 lb (0.5 kg) Boxed 1.4 lb (0.7 kg)

    Call for Price
  • Eutech TN 100 Water Turbidity meter- Jual Eutech tn 100|cv.Bunga Toba

    Specifications

    Product Specification

    Description
    Measuring Parameter Turbidity
    Highlights Light weight, IP67 waterproof meter
    Principle Nephelometric non-ratio / ISO 7027 and DIN 27027 compliant
    Range 0 to 2000 NTU
    Automatic Range Selection 0.01 to 19.99 NTU;
    20.0 to 99.9 NTU;
    100 to 2000 NTU
    Resolution 0.01 NTU (0 to 19.99 NTU);
    0.1 NTU (20.0 to 99.9 NTU);
    1 NTU (100 to 2000 NTU)
    Accuracy < 0.1 NTU for 0.02 NTU standard;
    ±2 % of reading ±1 digit for 0 to 500 NTU;
    ±3 % of reading ±1 digit for 501 to 2000 NTU
    Repeatability < or = ±1 % of reading
    Calibration Up to 4 points
    Calibration Standards 0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU
    Response Time < 6 secs for full step change
    Sample Volume 10 mL
    Light Source Infrared-emitting diode (850 nm wavelength)
    Operating Temperature Range 0 to 50 ºC
    Sample Temperature Range 0 to 50 ºC
    Enclosure Type & Rating ABS plastic & IP67 rated
    Power 4 x 1.5 V ‘AAA’ alkaline batteries (> 1200 readings)
    Certifications/Compliance FCC part 15 class A, TUV 3 in 1, CE, RoHS
    Dimensions (LxWxH) Meter: 15.5 x 6.8 x 4.6 cm
    Boxed: 35.5 x 16.5 x 10.5 cm
    Weight Meter: 200 g
    Boxed: 1,160 g
    Call for Price
  • Expert ph meter Eutech – Jual ph meter eutech- cv.Bunga Toba

    Spesifikasi:

    Model
    Eutech™ Expert pH
    pH – range : 0,0 – 14,0
    pH – resolution:0,1
    pH – accuracy: ±0,1
    pH – calibration
    Up to 3 points
    Temperature range (°C)
    0…+50,0
    Temperature resolution (°C)
    0,1
    Temperature accuracy (°C)
    ±0,5 + 1 least significant digit
    Temperature compensation
    Automatic
    Power supply
    Four batteries (A76 or LR44)
    W×D×H (mm)
    170×45×30
    Compliance
    IP67

    Call for Price
  • Eyewash Haws 7501| Penjual alat cuci mata eyewash Haws 7501 CV.BUNGA TOBA

    Eyewash

    Emergency eyewash haws

    Spesifikasi:
    Emergency eyewash Merk: HAWS
    Tipe: 7501
    Model 7501 portable gravity operated eyewash shall include
    a FDA approved high-density green polyethylene 9 gallon
    (34.1 L) tank, ABS plastic eyewash heads with .4 gpm (1.5 L)
    flow rate over 15 minutes, yellow pull-down activation arm,
    integral handle on top, wide-fill threaded cap, sign-mounted
    operating instructions, and stainless steel wall bracket (unit
    must be hung). Additive not included – Order separately

    Call for Price
  • FGBB423BAL- 02X Tokico Flow meter- Tokico 1/2 Inch- Flow meter minyak Tokico

    Flow meter Tokico

    STANDARD SPECIFICATIONS
      Bore (mm)   15
      Accuracy   ±0.5%
      Flow Range   40  ̴  200 L/H
      1,2  ̴  3cP
      Diesel, Light Oil
      Flow Range   5 – 200 L/H
      10cP
      Heavy Oil
      Max. Working   10 kgf/cm²
      Pressure
      Hydraulic Test   20 kgf/cm²
      Pressure
      Max. Working   Standard  : 80°C for diesel & light oil
      Temperature   Optional   : 120°C for heavy oil
      Flange Rating   JIS 10 kgf/cm²FF
      Material – Body   Cast Iron (FC25)
      Material – Rotor   Resin
      Counter Unit   Integrating pointer and
      integrating counter
      (a reset counter is also available)
      Flow Direction   Right → Left
      Paint Color   Munsell 1.4PB3.1 1/2″
    Call for Price
  • Jual Flow meter Minyak Fill Rite

    Flow meter Fill Rite
    Tipe: series 900 c
    Description: 4 Digit
    Flow Rate (GPM/LPM) : 6-40 / 23-151
    mAX pRESURE ( psi/bar) : 50/ 35
    inlet/ outlet : 1,5 inchi
    compatible Fluid: Gasoline, Disel, B2O,e15,kerosen

    Call for Price
error: Content is protected !!
WhatsApp chat